320 Troubleshooting your Enterprise Edge system
Enterprise Edge 2.0 Programming Operations Guide P0911588 Issue 01
5. Check with your T1 or PRI service provider to see if through-fed repeaters are
used on the T1 or PRI span. The EE-DTM does not provide the DC
connection required for through-fed repeaters. If through-fed repeaters are
used on the T1 span, disable the internal CSU and connect the EE-DTM to an
external CSU.
6. If the problem persists, replace the EE-DTM.
For information on how to replace any system components, refer to theEnterprise
Edge Installation and Maintenance Guide
Monitoring the T1 or PRI signal
If you are finding minimal faults with the T1 or PRI signal, you can monitor the
signal to try and isolate the problem. The monitor jack on the EE-DTM faceplate
provides non-intrusive, bridged in-service monitoring of the T1 or PRI signal.
Connect a protocol analyzer orothertest equipment into the monitorjackto monitor
the signalreceivedfrom the network, and the signal transmitted by Enterprise Edge.
Problems with Trunk or Station Modules
1. Choose Resources, Media Bay Modules and the bus that the module is on to
ensure that the module is not disabled. For more information, refer to the
procedure, Display the Media Bay Module status on page 279.
2. Disable the module using the procedure, Disable a module on page 279.
3. Enable the module using the procedure, Enable a module on page 280.
4. For an EE-DTM, EE-CTM or EE-DSM:
Check the external line by terminating a single-line telephone directly on the
distribution block, or equivalent, which connects to the Trunk Module.
5. For the EE-ASM:
If the EE-ASM is still down, power down, then power up the Enterprise Edge
system.
Notify service provider of T1 or PRI signaling disruption.
Notify your T1 or PRI service provider before disconnecting your T1 or PRI
lines, removing power to your system, or performing any other action that
disrupts your T1 or PRI signaling. Failure to notify your T1 or PRI service
provider may result in a loss of T1 or PRI service.