Maintenance 291
P0911588 Issue 01 Enterprise Edge 2.0 Programming Operations Guide
Companion event messages (North American systems only)
Table 1 Event messages
Event message display Cause
Evt:275-3546 S8 (U.S. only) Unable to activate all registered portables. The
system ran out of portable credits. One event is generated per
portable that failed to activate. The repetition of the
corresponding alarm code 59 indicates how many additional
credits must be purchased.
Evt:301-1031 S5 The Base Station (on port 0103 in this case) cannot successfully
receive the data image.
Both radios belonging to the Base Station are disabled. This
may occur if the flash EEPROM is faulty. Two events are
raised: one for the B1 channel radio (as in this case) and another
for the B2 channel radio. A corresponding alarm code 53
occurs.
Evt:302-1031 S5 The Base Station (on port 0103 in this case) cannot be written to
during data transfer.
Both radios belonging to the Base Station are disabled. The
Base Station’s flash EEPROM is faulty. Two events are raised:
one for the B1 channel radio (as in this case) and another for the
B2 channel radio. A corresponding alarm code 53 occurs.
Evt:303-1031 5 The Base Station (on port 0103 in this case) cannot be
synchronized with the other Base Stations in the system.
Both radios belonging to the Base Station are disabled. The
Base Station hardware is faulty. Two events are raised: one for
the B1 channel radio (as in this case) and another for the B2
channel radio. A corresponding alarm code 53 occurs.
Evt:304-1032 A B2 channel radio (radio 2 on port 0103 in this case) cannot be
synchronized with other radios because of system overload.
Evt:305-01032 S5 A B2 channel radio (radio 2 on port 0103 in this case) cannot be
synchronized because the B1 radio was disabled in
maintenance.
Both radios belonging to the Base Station (on port 0103 in this
case) are disabled. The B1 radio must be operational to
synchronize both radios of the Base Station with other radios in
the system. Two events are raised: one for the B1 channel radio
and another for the B2 channel radio. A corresponding alarm
code 53 occurs.
Evt:306-01031 S5 A radio (0103-1 in this case) cannot be synchronized because
there are no B2 channel radios.
Both radios belonging to the Base Station (on port 0103 in this
case) are disabled.Two events are raised: one for the B1 channel
radio in this case) and another for the B2 channel radio. A
corresponding alarm code 53 occurs.
Evt:307-0109100 S5 A recoverable RIM fault has occurred
The RIM is reset. If a link is active when this error occurs, the
link is dropped. The radio (0109-1 in this case) is returned to
service.
Commentaires sur ces manuels