646 Chapter 67 Configuring IP Filter Rules
N0060606N0060606
Accessing Element Manager through the Firewall
• Do not set any blocking inbound rules on the interface that you use to connect to BCM using
Element Manager. This includes enabling the default rules.
• Configure the rule as follows:
Table 158 Inbound Rule Configuration for Element Manager - TCP
Type of filter Inbound Filter
Protocol TCP
Source IP Type Fixed
Source IP IP address of the system that will access BCM
Source Range Mask 255.255.255.255 (or as appropriate)
Source Port Range ALL
Destination IP Type Fixed (or Dynamic if the IP address is remotely assigned)
Destination IP IP address for this interface (or blank if IP Type is Dynamic)
Destination Range Mask Appropriate mask (or blank if IP Type is Dynamic)
Destination Port Range 5989-5989
Note: This rule must come before more general rules.