Chapter 45 Configuring VoIP trunk gateways 419
BCM 4.0 Networking Configuration Guide
Configuring a remote gateway (H.323 trunks)
The following explains how to configure the BCM to communicate with other BCMs and/or other
VoIP gateways such as Meridian IPT using H.323 trunks. The remote gateway list must contain an
entry for every remote system to which you want to make VoIP call.
Gatekeeper note: If your system is controlled by a gatekeeper, you do not need to establish these
gateways. Refer to “VoIP interoperability: Gatekeeper configuration” on page 423.
The following path indicates where to access the remote gateway in Element Manager:
Element Manager: Configuration > Resources > Telephony Resources > Routing Table
To configure a remote gateway
1 On the Modules panel, in the Module type column, select the IP Trunks line.
2 In the bottom panel, select the Routing Table tab.
3 Click Add.
4 The Add Remote Gateway dialog box appears. See Figure 134.
5 Enter a Name and Destination Digits for the remote gateway.
6 Click OK.
7 Enter the appropriate information for the remote system.