530 Chapter 61 Data modules
N0060606N0060606
4 Click Add.
The Add Lines Assignment dialog appears.
5 In the Add Lines Assignment dialog box, enter the line number of one of the line assigned to
the Data Module.
6 Click OK.
7 Click Save.
8 If you are adding all of the lines to a single Interface, repeat steps 4 to 7 for each line you want
to assign to the Data Module.
If you are adding the lines to multiple Interfaces, repeat steps 4 to 7 for each line you want to
assign to the Data Module.
Removing a line assignment
If you decide you want to remove a line assignment from the Data Module and use it as a
telephony line, use the procedure below:
To remove a line assignment
1 Click Configuration > Resources > Telephony Resources.
2 Click the Bus number assigned to the Data Module.
The details panel appears.
3 In the details panel, click the Data module Fixed Line Assignment tab.
The Assigned Lines table appears.
4 Click on the line number you want to remove.
5 Click Delete.
6 On the confirmation dialog box, click Ye s .
Configuring the DDI Mux to work with the DTE
After you have assigned the lines to the data module, you need to configure the DDI Mux so it can
work with the DTE.
1 Click Configuration > Resources > Telephony Resources.
2 Click the Bus number for the Data Module portion of the DDI Mux.
The details panel appears.
Note: You can add all of the lines to the single Interface, or you can the lines to
multiple interfaces.
Note: You can assign up to 24 lines to the DDI Mux.
You can assign only Fixed lines.