Avaya BCM 4.0 Networking Guide de configuration Page 107

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 758
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 106
Chapter 6 Configuring resources — media bay modules 107
BCM 4.0 Networking Configuration Guide
Analog station
module
Analog Station Media Bay
Module (ASM 8)
Single density
ASM8 = 2 per bus/8 analog
sets for each module
Double density
ASM8 = 4 per bus/16 analog
sets for each module
N/A
(Global) Analog Station
Media Bay Module
(GASM)
Single density
2 per bus/8 analog sets for
each module
Double density
4 per bus/8 analog sets for
each module
Provides CLID passthrough,
Message Waiting Indication* and
Disconnect Supervision*
(*available features depends on
market profile)
Norstar analog station
module (ASM) connected
to a FEM
FEM = 1 per bus/16 digital
sets
N/A
Trunk module Digital Trunk Media Bay
Module (DTM)
DTM = 1 per bus/16 lines
(max. three DTMs on a
system)
DTMs can be set to module
types: Loop, E&M, DID, T1,
PRI (NI-2 or ETSI are
region-specific)
CLID Trunk Media Bay
Module (CTM4 or CTM8)
Global Analog Trunk
Module (GATM4 or
GATM8) (released with
BCM version 3.5)
CTM4/GATM4=1 per offset/
4 lines per module
CTM8/GATM8= 2 per bus/
8 lines per module
CTMs/GATMs can be set to
module types: Loop
4X16 Media Bay Module
(4X16) (counts as one
CTM)
4X16= 1 per offset (4 lines)
and additional bus (station)
4X16s can be set to module
type: Loop
BRI Media Bay Module
(BRI)
BRI= 3 per bus, 4 loops (8
lines) per module
BRI can be set to module
types BRI S/T, BRI U2, BRI
U4 (setting must match
physical module type). U2
and U4 are region-specific
Specialized
modules
Norstar trunk expansion
modules, with Analog
Trunk cards, connected to
a FEM
FEM= 1 per bus, can
support up to three analog
trunk cards (in one trunk
expansion unit)/4 lines each
Norstar analog trunk cards:
Loop, E&M, DID
DDI MUX 1 per bus T1 (telephony and data).
Refer to “Configuring the DDI
Mux module” on page 525.
Norstar trunk expansion
modules with BRI cards,
connected to a FEM
FEM= 1 per bus, can
support up to three BRI
cards (in one trunk
expansion unit)/4 loops each
Norstar BRI cards: BRI S/T,
BRI U2, BRI U4 (setting must
match physical module type).
U2 and U4 are
region-specific
Data module Refer to the data section of this book (“Configuring a data module” on page 532) for details about
setting up a data module on DS30 08. This process includes any Norstar Data Modules connected
to a FEM.
Table 20 Programmed Bus Types (Sheet 2 of 3)
Programmed
Bus Type Hardware unit Capacity
Available line types (some line
types are region-dependent)
Vue de la page 106