52 Telephony metrics monitoring
Nortel Business Communications Manager 5.0
Fault and Performance Management
NN40170-701 01.01 Standard
August 2009
Copyright © 2009 Nortel Networks
4 Click the B-channel you want to enable or disable (B1 or B2).
5 Select Enable or Disable.
If you are disabling the channel, you are prompted by a dialog box to confirm
your action. The State box indicates the mode of operation for the port. If the
port is enabled, this box is blank unless a device is physically connected.
--End--
Provisioning a PRI B-channel
When you purchase PRI from your service provider, you can request the
number of B-channels that are allocated for you to use. For example, you can
use 12 B-channels. If you do not have all of the PRI B channels, disable all the
B-channels that you do not need.
Prerequisites
Nortel recommends that the number of lines you deprovision on a DTM
(configured as PRI) be the same as the number of B-channels that you
disable. For example, if the DTM is on Expansion 1, when you disable B-
channels 13 to 23, you should deprovision lines 77 to 87.
Procedure steps
Step Action
1 Select Administration > Telephony Metrics > Trunk Module Metrics.
2 Choose a module.
3 Click B-channels.
A list of the B-channels on this module appears.
4 Click a channel, for example, B 01.
The display shows the status of the PRI channel.
5 Click the Enable or Disable button to change the setting for the channel.
--End--
Trunk module CSU statistics
Each trunk module has an internal channel service unit (CSU). When
enabled, the internal CSU monitors the quality of the received T1 signal and
provides performance statistics, alarm statistics, and diagnostic information.
Trunk modules must be individually programmed to establish parameters for
collecting and measuring transmission performance statistics by the CSU.