Avaya Business Communications Manager 5.0 - Fault and Performance Management Manuel d'utilisateur Page 25

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 70
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 24
Using the BCM fault management system 25
Nortel Business Communications Manager 5.0
Fault and Performance Management
NN40170-701 01.01 Standard
August 2009
Copyright © 2009 Nortel Networks
Clearing an alarm from the alarm set
Use the following step to clear an alarm from the alarm set.
Procedure steps
Step Action
1 On the alarm set, press the Clear soft key. The alarm is cleared from the
alarm set.
--End--
Responding to LED indicators
Use the Business Element Manager to reset the Status LEDs on the front
panel of the BCM to a normal state.
Reset the status LED
Use the following steps to reset the status LED.
Procedure steps
Step Action
1 Click the Administration tab.
2 Open the General folder, and then click the Alarms task.
The Alarms pane opens
3 On the Alarms pane, click the Reset LEDs button.
The Status LED on the front panel of the BCM is reset from red to normal
operation green.
--End--
Configuring alarm behavior
Configure alarm behavior to specify the following settings for alarms:
the maximum number of alarms to display in the Alarms Panel (from 100
to 1000)
whether to enable or disable SNMP traps for selected alarms; if you have
specified an SNMP trap destination, by default you will receive all Critical
and Major alarms
Vue de la page 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 69 70

Commentaires sur ces manuels

Pas de commentaire