Avaya Business Communications Manager 5.0 - Fault and Performance Management Manuel d'utilisateur Page 35

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 70
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 34
System metrics monitoring 35
Nortel Business Communications Manager 5.0
Fault and Performance Management
NN40170-701 01.01 Standard
August 2009
Copyright © 2009 Nortel Networks
Configuring the QoS monitor
You configure the QoS Monitor using the QoS Monitor panel on the
Administration tab. You can configure the following:
the monitoring mode
logging parameters
Procedure steps
Step Action
1 Click the Administration tab.
2 In the Navigation tree, click System Metrics >QoS Monitor.
3 From the Monitoring Mode drop-down menu, select a monitoring mode.
--End--
Configuring QoS logging attributes
Configure the logging attributes to set the size and frequency of QoS logs.
Procedure steps
Step Action
1 Click the Administration tab.
2 In the Navigation tree, click System Metrics>QoS Monitor.
3 In the Logging area, select or clear the Enable Logging check box.
4 In the Maximum log file size field, type the value of the maximum log size
allowed.
Table 6 Variable definitions
Variable Value
Disabled
Enabled in Link-Monitor mode Continuously test the connection between the BCM and remote
endpoints.
Enabled in QoS-Monitor mode Select this option if you want to calculate MOS values for each
endpoint, determine whether the connection has fallen below a
specific threshold, send MOS scores to FCAPS applications, and
create a log history of the MOS scores.
Vue de la page 34