System metrics monitoring 37
Nortel Business Communications Manager 5.0
Fault and Performance Management
NN40170-701 01.01 Standard
August 2009
Copyright © 2009 Nortel Networks
UPS metrics
BCM can support an Uninterruptible Power Supply (UPS) device to ensure
continuous operation during power interruption and failure conditions. The
UPS feature provides power source monitoring and battery backup so that
critical system functionality required to maintain and provide warning time to
either correct the problem or to activate a contingency plan for impacted
services is possible. UPS is described in Nortel Business Communication
Manager 450 5.0 Installation—System (NN40170-303) and BCM450 5.0
Installation Checklist and Quick Start Guide (NN40170-302) or the BCM50 5.0
Installation Checklist and Quick Start Guide (NN40170-308).
The UPS connects and communicates with the BCM through USB. Enable the
UPS feature by plugging the UPS USB cable into the BCM USB connector
before you power up the BCM. The UPS must be present during the boot up
process for the BCM to function.
G.711 Displays the current MOS value calculated when using a G.711
aLaw codec to transmit VoIP packets to this Remote Gateway.
The MOS can be a value from 0.00 to 5.00, where 0.00 is the
worst score (Poor) and 5.00 is best score (Excellent).
G.723-5.3kbit/s Displays the current MOS value calculated when using a G.723
5.3 kbit/s codec to transmit VoIP packets to this Remote
Gateway.
The MOS can be a value from 0.00 to 5.00, where 0.00 is the
worst score (Poor) and 5.00 is best score (Excellent).
G.723-6.3kbit/s Displays the current MOS value calculated when using a G.723
6.3 kbit/s codec to transmit VoIP packets to this Remote
Gateway.
The MOS can be a value from 0.00 to 5.00, where 0.00 is the
worst score (Poor) and 5.00 is best score (Excellent).
G.729 Displays the current MOS value calculated when using a G.729
codec to transmit VoIP packets to this Remote Gateway.
The MOS can be a value from 0.00 to 5.00, where 0.00 is the
worst score (Poor) and 5.00 is best score (Excellent).
G.729A Displays the current MOS value calculated when using a G.729A
codec to transmit VoIP packets to this remote Gateway.
The MOS can be a value from 0.00 to 5.00, where 0.00 is the
worst score (Poor) and 5.00 is best score (Excellent).