Using Technician Interface Software
8-32 114088 Rev. A
When you issue the Technician Interface diags command to test and reboot a
specific module, the test and reboot process may take anywhere from 2 1/2
minutes to 10 minutes to complete, depending on the memory configuration of the
board. For example, when you issue the
diags command for a FRE-2 processor
module with 8 MB of DRAM, the process takes approximately 3 minutes to
complete. When you issue the
diags command for a FRE-2 processor module
with 32 MB of DRAM, the process takes approximately 10 minutes to complete.
Turning off the DIAG Indicator LED
The DIAG LED lights during diagnostics and goes out after diagnostics have
determined that the processor module and its associated link module are
functional. If they are not functional, the DIAG LED on the front panel and LED 8
on the FRE processor module daughterboard remain on. If this occurs, make sure
the modules are seated properly in the router and issue the
diags command again.
Call your Bay Networks Technical Response Center if the DIAG LED does not go
out.
If you hot-swap a Link Module, the diagnostics do not automatically run and the
Fail LED on that module may remain ON. In this case, you can enter the
following command to switch off the Fail LED:
diag -l
<slot_number>
If you do not specify a slot number, the command switches off the Fail LED on all
slots.
Displaying the Software Version
Enter stamp to display the current software version and the date and time it was
created.