Vue de la page 186
System Administration
114088 Rev. A 8-23
Restarting After Crossnet Shutdown Notification (BNX Only)
On BNX platforms only, you can use the -shutdown option of the restart
command to restart the GAME image on one or more slots, following a “graceful
crossnet shutdown”on the same slots. With this option, the system notifies the
remote end of any associated Frame Relay Switch (frsw) PVCs to expect a loss of
connectivity. (The BNX sends to the remote end of each PVC an update message
packet with the A-bit set to“inactive.”)
To initiate graceful shutdown followed by a system or slot restart, enter the
appropriate command at the Technician Interface prompt:
The console displays the following message during shutdown:
Shutdown in progress.
If shutdown succeeds, the console displays the message
Shutdown is complete.
Upon issuing this message, the system performs a restart operation.
If shutdown fails, the console displays the message
Continue shutdown? (Y/N)
If you choose “N” (no) at this time, the system terminates shutdown and displays
the following message on the console device:
Shutdown aborted.
Upon issuing this message, the system performs a restart operation.
If you enter:
The system performs
a graceful shutdown
and restarts
restart -shutdown
All slots
restart -shutdown [
<slot_no.>
]
One slot
restart -shutdown [
<slot_no.>-<slot_no.>
]
A range of slots
restart -shutdown [
<slot_no.>
,
<slot_no.>
,. . . ,]
A list of slots