Using Technician Interface Software
6-4 114088 Rev. A
After log -i
or log -x,
enter: Followed by: To specify:
-e
<entity_name>
The name of the software service for which the
router will log (write) event messages to the local
events log, or exclude from the events log. When
you specify an <entity_name>, you must
Use uppercase letters.
Enter the <entity_name> in quotes when that
name contains spaces (for example,
“FRAME RELAY”).
See
Event Messages for Routers and BNX
Platforms
for a list of router software entity names.
-f
<severity_levels>
The severity levels of messages that the router will
log (write) to the local events log, or exclude from
the events log.
The severity codes are
f or F for fault
i or I for informational
t or T for trace
w or W for warning
d or D for debug
(Debug events are for use and interpretation by Bay
Networks Technical Response Center personnel
only.)
You can specify in the same log command one or
more severity codes. For example, enter log -i -fwi
to specify a filter that writes only Warning and Info
messages to the events log.
-s
<slot_numbers>
The number of the slot(s) on which the router will
write event messages to the local log buffer.