Configuring Traffic Filters and Protocol Prioritization
B-4
308645-15.0 Rev 00
Chapter 6 provides detailed procedures for creating inbound traffic filters and
traffic filter templates.
6. Click on
Create
. The Create Filter Template window for the
selected protocol opens.
7. Specify a descriptive name in the Filter
Name field.
8. Choose Criteria > Add >
criterion
.
See Table B-1 or Table B-2 for specific
examples.
The Add Range window opens.
(If you selected the User-Defined
criterion, the Add User-Defined Field
window opens first.)
9. Type a minimum and maximum value to
specify the range, then click on
OK
.
See Table B-1 or Table B-2 for specific
examples. To specify additional ranges,
choose Range > Add.
The Add Range window closes. The new
criterion and ranges now appear in the
Filter Information field of the Create Filter
Template window.
10.Choose Action > Add >
action
.
See Table B-1 or Table B-2 for specific
examples.
The action appears in the Filter
Information field.
11. Click on
OK
. The Filter Template Management window
opens. The new template appears in the
templates list.
12. Click on
Done
. The Filters window opens.
13. Click on
Create
. The Create Filter window opens.
14. Specify a descriptive name in the Filter
Name field.
15.Select a template in the Templates field.
16. Select a circuit in the Interfaces field.
17. Click on
OK
. The Filters window opens.
18. Click on
Apply
. The filter is applied to the circuit.
Site Manager Procedure (continued)
You do this System responds