Configuring Traffic Filters and Protocol Prioritization
7-20
308645-15.0 Rev 00
Specifying User-Defined Criteria
The Edit Priority/Outbound Filters window and Edit Priority/Outbound Template
window provide a User-Defined criterion option.The User-Defined option allows
you to set up a user-defined criterion based on bit patterns in the packet’s data link
or IP header that are not supported in predefined criteria.
Adding user-defined criteria is similar to adding predefined criteria, except you
must specify the criterion’s location in the packet. (With predefined criteria, the
locations are established.)
See Chapter 4 for the supported IP and data link header reference points you can
use to specify user-defined criteria for outbound traffic filters.
To add a user-defined criterion:
Site Manager Procedure
You do this System responds
1. Display the Edit Priority/Outbound
Template window (Figure 7-6) or Edit
Priority/Outbound Filters window
(Figure 7-8).
2. Choose Criteria > User-Defined. The Add User-Defined Field window
opens (Figure 7-9).
3. In the REF field, choose the header
reference point.
4. In the OFFSET field, specify a bit offset
from the reference point.
5. In the LENGTH field, specify the length of
the criterion.
6. In the Minimum value and Maximum value
fields, specify a range for the criterion.
7. Click on
OK
. The Edit Priority/Outbound Template
window or Edit Priority/Outbound Filters
window opens.
8. Continue editing the template or filter.
See Table 7-1, “Using the Edit Priority/
Outbound Template Window,” or Table 7-2,
“Using the Edit Priority/Outbound Filters
Window.”
Commentaires sur ces manuels