290 Table: eIO_MODULE
The current implementation of eIO is limited to configurations of up to eight
modules attached to one FP-1000 controller module. Nortel recommends
starting the first module with number 01 and incrementing by 1 for the
other modules.
Note:
Specify the leading 0 in the numbering (enter the value 01, not 1).
An authorized of an entry typically found in this field is as follows: 01
eIOM_Type_str
The current release supports the following modules:
Table 20
eIOM supported modules
FP-AI-100 Analogue input
8 contacts
FP-DI-300 Digital input
8 contacts
FP-DI-301 Digital input
16 contacts
FP-DI-330 Digital input
8 contacts
FP-DI-401 Digital output
8 contacts
Refer to the corresponding chapter in this document for technical
specifications on the modules.
An authorized of an entry typically found in this field is as follows:
FP-DI-330
eIOM_Url_str
This field denotes the URL string associated with the module. Refer
to the FieldPoint Explorer and other National Instrument distributed I/O
documentation resources for more information on the URL defined OPC
server binding mechanism.
The FieldPoint Explorer is a recommended way to determine naming
conventions. Take note of the ending characters specified in Table 21
"eIO_module sample data" (page 291). Using an incorrect URL prevents
binding contacts to the OPC Server, resulting in system malfunction.
An authorized of an entry typically found in this field is as follows:
opc:/National Instruments.OPCFieldPoint/FP Res\FP-AI-100 @1\Channel
eIOM_Contact_cnt_n
The field defines the number of contacts that are associated to the module.
This field can specify a smaller number than the maximum number of
physical available contacts on a module, in which case the remaining
contacts are not bound to the OPC Server and remain non-operational.
Nortel Communication Server 1000
DECT Messenger Installation and Commissioning — Book 2
NN43120-301 02.01 4 June 2010
Copyright © 2003-2010 Nortel Networks. All Rights Reserved.
.
Vue de la page 289
1 2 ... 285 286 287 288 289 290 291 292 293 294 295 ... 455 456

Commentaires sur ces manuels

Pas de commentaire