318 Table: eKERNEL_ALARM
A special value *OTHER can be defined. If specified, the *OTHER
description is used to handle alarms that were not identified by a qualified
description.
Alarms with descriptions that do not either match a qualified description
or the value *OTHER, are ignored.
Refer to other reference material for detailed instructions for each alarm
system. The following authorizeds are provided to clarify the usage:
Example 1: ELDAD If the alarm is described as ELDAD, alarms are
sent where behavior depends on a tone code. Alarms with tone code 1,
2, 3 and 4 each have different characteristics, and need different alarm
handling. In the case of ELDAD define the ALA_Descr_str values 1, 2, 3
and 4 for the 4 corresponding records.
Example 2: TELEVIC TELEVIC sends alarms where behavior depends
on tone code or message contents.
If the alarm is described as TELEVIC, the system looks first for a string
pattern (first blank or first xx characters as specified in the L:xx description
of the INPGM_Model_str field of the eKERNEL_INPGM table (PROTOCOL
CONVERTOR L:03). If no length (L:xx) is specified, the default value is
3. Characters of message or search until first blank character: NUR, SAN,
ASS, REA, MUG, and so on.
See documentation Table eKERNEL_inpgm.pdf.
If no such definition is found; the system looks for a matching tone code
pattern (for authorized, 0, 1, 2, 3, 4, 5, 6, 7, 8, 9 or 0).
If again no definition is found, the system looks for an *OTHER definition.
Example 3 - National Instruments The National Instruments distributed
I/O modules FP-DI-300, FP-DI-301 and FP-DI-330 generate discrete input
alarms, the I/O module FP-AI-100 generates analogue input alarms. Both
modules are configured in eIO_MODULE, eIO_AI and eIO_DI tables. In
the latter two files the alarm type can be defined, default is D-INPUT and
A-INPUT. If these defaults are used, ALA_Descr_id_str must have records
for D-INPUT and A-INPUT.
Example 4 - Guarding A special feature in the eCAP input program
consists of a method to verify the amount of time between two requests. If
a specific type has elapsed, this can be caused by a failure in the external
alarm system or the physical interface. In such case, GUARDING can be
implemented. This is configured in the eKERNEL_GUARDING table. The
link between eKERNEL_GUARDING and eKERNEL_ALARM is performed
Nortel Communication Server 1000
DECT Messenger Installation and Commissioning — Book 2
NN43120-301 02.01 4 June 2010
Copyright © 2003-2010 Nortel Networks. All Rights Reserved.
.