Avaya CS1000 Manuel d'utilisateur Page 256

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 456
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 255
256 Table: eDMSAPI
For example, if 1 is specified, alarms with alarm priority of 1 are handled
as emergency messages, whereas alarms with priority of 2, 3, 4, and so
on are handled as urgent or normal messages. Nortel recommends that
you carefully evaluate the consequences of changes to this field, for two
reasons:
Emergency messages impact the DECT C4060 user (different tone,
user intervention required for acknowledge).
Emergency messages impact throughput, because normal message
allocates a datapath a few seconds, while urgent messages can
allocate more than 30 seconds, depending on the timeout value
specified for user confirmation.
An example of an entry typically found in this field is as follows: 1
eDMSAPI_api_address_str
This field specifies the IP address of the CSTA Service.exe module. In
most cases this is the same value as the local IP address of eKERNEL,
and can be obtained with IPCONFIG.exe.
An example of an entry typically found in this field is as follows:
10.110.50.138
eDMSAPI _API_port_str
This field specifies the port to which CSTA Service.exe listens, and (in the
current release) must always be set to 59000.
An example of an entry typically found in this field is as follows: 59000
eDMSAPI _PBX_address_str
This field specifies the IP address of the PBX. The information is
distributed to CSTA Service.exe, which handles the sockets connection
between DECT Messengerand the PBX. Contact the switch administrator
to obtain the IP address of the switch. If a different addressing scheme or
subnet mask is in use, appropriate TCP/IP network configuration must be
performed on both platforms (default gateway, additional interface, and
so on).
An example of an entry typically found in this field is as follows:
10.110.49.171
eDMSAPI_PBX_port_str
This field specifies the port to which the PBX listens, and depends on the
PBX type. In previous releases, the recommended value was 2555, which
is the default port to which a SOPHO DMC listens. Starting from R3.0,
there is also support for DAP controller and Nortel. The recommended
Nortel Communication Server 1000
DECT Messenger Installation and Commissioning — Book 2
NN43120-301 02.01 4 June 2010
Copyright © 2003-2010 Nortel Networks. All Rights Reserved.
.
Vue de la page 255