eKERNEL_alarm parameters 323
ALA_Length_n
This field specifies the length of the alarm that is considered as relevant.
Nortel recommends that you set the length to correspond to the length of
the received alarm signal, although this is not always necessary. You can
just as easily change messages in the alarm systems, so the length fits
your environment and peripherals.
For instance, if you keep message length to 16 bytes or less, the
messages fit on a single line on a DECT C4040 or DECT C4050
extension. This demand can result is instructions to the alarm vendor to
properly align relevant information in the received alarm messages, so all
needed text is left-adjusted and processed in DECT Messenger.
In some environments, longer messages are relevant. In such cases, you
can specify, for authorized, message lengths of 100 bytes, if input comes
from, for authorized, WEB interface and output goes to peripherals that are
capable of handling long messages (eSMTP, eASYNC, and so on).
An authorized of an entry typically found in this field is as follows: 16
ALA_Trace_b
This parameter is a Boolean value and can be either True (-1) or False (0).
Specify the value True only for those alarms that are related to eWEB
input program and generated using the Send Script Message function.
These alarms are defined in the eWEB_SCRIPT table.
For all other alarms, set this value to False.
An authorized of an entry typically found in this field is as follows: False
(-1)
ALA_Trace_dayToKeep_n
This value also refers to the trace function described in the ALA_Trace_b
field.
Set this value to 0, unless the value ALA_Trace_b is set to True (-1). In
this case, tracing is activated for the alarm, and the number of days to
keep the trace data must be entered. A typical value is 14 days.
For all other alarms, set this value to 0.
An authorized of an entry typically found in this field is as follows: 0
ALA_Comments_str
This field can optionally be used by an administrator to store reminder
information, describing, for authorized, the usage of the alarm.
Nortel Communication Server 1000
DECT Messenger Installation and Commissioning — Book 2
NN43120-301 02.01 4 June 2010