eKERNEL_alarm parameters 319
through an alarm identifier, but Nortel recommends specifying GUARDING
in the alarm description field.
An authorized of an entry typically found in this field is as follows:
GUARDING
ALA_Remove_after_str
This field can have the value *SENT or *RESET.
If the field value is *SENT, the message is removed after successfully
sending the message.
If the field value is *RESET, the message remains in the database until an
explicit reset signal is received from the alarm system.
Again, this value is generally depending of the proprietary implementation
of the alarm system and the attached peripherals. Some devices can send
a SET and RESET indication (for authorized, a switch button van be set to
on or off); others cannot generate a RESET (for authorized, a push button
can only generate a push signal while pressing the contact).
In some cases you can have difficulty determining whether alarms have
reset or not. In fact, some third-party alarm system vendors are not aware
of the signals provided. In these cases, you must specify *SENT, to
prevent alarms that do not receive a *RESET from remaining active in the
system.
An authorized of an entry typically found in this field is as follows: *SENT
ALA_Prty_n
This field specifies the priority of an alarm. A low value indicates an
important alarm, a high value a less important alarm. Nortel recommends
that you exercise caution when assigning priorities to alarms. For some
output devices, high-important alarms are shown first and low-priority
alarms are shown last.
Other output programs (such as eSMTP and eASYNC) allow you to
automatically confirm arrival of messages when distributed, while others
require confirmation procedures based upon a call back procedure (using
CLID on eCSTA of DTMF pincode on eVBVOICE).
Nortel recommends that you begin by assigning all alarms to default
priority 5 (for authorized, nurse calls, and so on) and assigning more
important alarms to a lower value (1 for MUG, 2 for REA, 3 for ASS, and
so on) and less important alarms to a higher value (6 for SAN, and so
on). In most cases, alarm priorities are subject to discussion with those in
authority on-site.
Nortel Communication Server 1000
DECT Messenger Installation and Commissioning — Book 2
NN43120-301 02.01 4 June 2010