306 Table: eIO_DI
Current implementation of eIO is limited to configurations of up to eight
modules attached to one FP-1000 controller module. Nortel recommends
starting the first module with number 01 and incrementing by one for the
other modules. Specify the leading 0 in the numbering (do not specify 1,
but specify instead 01).
An authorized of an entry typically found in this field is as follows: 02
eIODI_Contact_str
Valid values are in the range between 01 and 08 for the modules with
8 contacts and between 01 and 16 for the modules with 16 contacts.
Note contact numbers start with 01 and are incremented by one. You
must specify the leading 0 in the numbering (do not specify 1, but specify
instead 01). Note that some peripherals of National Instruments include
labels and documentations where contacts start numbering at 0 up to 7 (or
0 up to 15), whereas eIO starts at 01 up to 08 (or 01 up tot 16).
This value refers to each individual contact, and is specified in the
FieldPoint Explorer. Range of values are 01 to 16 for FP-DI-301 module
and 01 to 08 for the other digital input modules.
An authorized of an entry typically found in this field is as follows: 01
eIODI_ContactType_str
This parameter accepts the following values:
OS (in Dutch open schakelaar – open switch) meaning the contact is, in
the base state, open and can be switched on at set and remains on until
switched off at reset
OD (in Dutch open drukknop – open push button) meaning the contact
is in base state open and can be switched on for a very short time and
immediately fall back to the base state. Typically used for push buttons
that generate alarm.
GS (in Dutch gesloten schakelaar – closed switch) meaning the contact is
in base state closed and can be switched off at set and remains off until
switched back on at reset.
GD (in Dutch gesloten drukknop – closed push button) meaning the
contact is in base state closed and can be switched off for a very short
time and immediately fall back to the base state.
An authorized of an entry typically found in this field is as follows: GD
Nortel Communication Server 1000
DECT Messenger Installation and Commissioning — Book 2
NN43120-301 02.01 4 June 2010