286 Table: eESPA_OUTBOUND_CFG
The Data identifier for the priority record type is 6.
Table 18
Example eESPAO_ALA_Prty_from/to_n values
Site Area
Alarm
from Alarm to Beepcode Priority
110212
11 3
5
31
1 1 6 999 9 3
When a <msgrqs> is sent to the eESPA with an alarm priority equal to 2
for pager 4567, a datablock is created with a beepcode 1 (data identifier
3) and a priority 2 (High) (data identifier 6). Therefore, all alarms with a
priority between 0 and 2 have these specifications.
Example datablock:
(RS: record separator, US: Unit separator
* Alarm priority equal to or between 0 and 2
1US4567RS2USExampleRS3US1RS6US2
* Alarm priority equal to or between 3 and 5
1US4567RS2USExampleRS3US3RS6US1
* Alarm priority equal to or between 6 and 999 (highest possible value)
1US4567RS2USExampleRS3US9RS6US3
An authorized of an entry typically found in this field is as follows: 0
eESPAO_ALA_Prty_to_n
See eESPAO_ALA_Prty_from_n
An authorized of an entry typically found in this field is as follows: 999
eESPAO_BeepCode_str
This field specifies the data that must be entered in the espa datablock for
record type beepcode (data identifier 3).
An authorized of an entry typically found in this field is as follows: 1
eESPAO_Priority_str
This field specifies the data that must be entered in de espa datablock for
record type priority (data identifier 6).
Nortel Communication Server 1000
DECT Messenger Installation and Commissioning — Book 2
NN43120-301 02.01 4 June 2010
Copyright © 2003-2010 Nortel Networks. All Rights Reserved.
.