Using Technician Interface Scripts
2-630
Sample Display – show x25 connections
X.25 Virtual Circuit Connections
Total VC Failed VC Normal VC Abnormal VC
Line Connections Connections Disconnects Disconnects
----- ----------- ----------- ----------- -----------
2.1 6 0 6 0
1 Connection Entries.
lines [
<slot.connector>
]
Displays the packet level configuration for all lines or for a specific line (slot and
connector). You can modify performance by turning Stats on or off. The table includes the
following information:
Failed VC Connections Number of unsuccessful VC connections performed since starting
up.
Normal VC Disconnects Number of normal VC disconnections.
Abnormal VC Disconnects Number of abnormal VC disconnections.
Line Line slot and connector.
State State of the line: Disabled, Down, Init (initializing), Not Present
(configured but not yet started), or Up.
Network type Type of network, which is one of the following:
• DTE – Data Terminating Equipment without restart procedure.
• DCE – Data Circuit Equipment.
• DTE/RES – Data Terminating Equipment with restart procedure.
• DTE/DTE – Unassigned roles.
Def Window Maximum window size allowed for each call if the line uses flow
control negotiation. If the maximum packet length (Def Packet) is
128 or more, an extended window size is up to 127. Otherwise the
maximum is 7.
Def Packet Maximum packet length allowed for each call if the line uses flow
control negotiation: 16, 32, 64, 128, 256, 512, 1024, 2068, 4096.
Commentaires sur ces manuels