Using Technician Interface Scripts
2-424
Sample Display – show packet capture 102101
Pkt# 1 06/24/94 06:59:03.018 CSMACD 52 Tx
00000000: 01 80 c2 00 00 00 00 00 a3 00 00 0c 00 26 42 42
00000010: 03 00 00 00 00 00 80 00 00 00 a3 00 00 0c 00 00
00000020: 00 00 80 00 00 00 a3 00 00 0c 80 01 00 00 14 00
00000030: 02 00 0f 00 20 20 20 6c 65 74 20 20 72 65 6d 20
configuration
<line number>
Displays the configuration of a specific Packet Capture line instance.
The configuration table displays the following fields, which are explained in more detail in
Using Technician Interface Software
.
<line number>
Physical interface to which the capture is connected. See the
capture
command.
Delete State of existence of the MIB instance: Created or Deleted.
Disable State of the Packet Capture instance: Enabled or Disabled.
State State of the Packet Capture subsystem, as follows:
•
Up
– Registered and enabled.
•
Down
– Registered but disabled.
•
Init
– Loaded but no interface registered for the instance.
•
Not Present
– Not loaded on the slot connected to the instance.
Fname Filename to use to retrieve the capture buffer.
Control Operation in effect: Start or Stop.
Capture State of the operation: Started or Stopped.
LineNumber Line number of the physical interface connected to the instance.
BufSize Size of the capture buffer in 1024-byte increments.
PktSize Number of bytes saved from a packet in 32-byte increments.
Direction Direction of capture: Receive, Transmit, or both.
Count Number of packets captured.