Avaya Using Technician Interface Scripts Manuel d'utilisateur Page 294

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 788
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 293
Using Technician Interface Scripts
2-242
show e1
The show e1
<option>
commands display configuration, status, and statistical information
about the E1 lines. For more information about E1, refer to Configuring Routers.
The
show e1 command supports the following subcommand options:
alerts
Displays all circuits that are enabled but not up. Use this display to identify the interfaces
that are not working. The table includes the following information:
alerts frame errors [circuit <circuit name>]
base [circuit <circuit name>] line errors [circuit <circuit name>]
disabled version
enabled
Slot Slot identifier; ranges from 1 to 14.
Conn Connector identifier: 1 or 2.
Circuit Name of the circuit associated with this line.
HDB3 Support Status of High Density Bipolar Coding: Enabled or Disabled.
HDB3 maintains sufficient “ones” density within the E1 data
stream without disturbing data integrity.
Clock Mode Source of the E1 transmit clock as follows:
Internal – Clock is generated internally.
Slave – Clock is derived from the incoming data stream.
Manual – Jumpers on the E1 link module determine the clock
source (internal or slave.)
Vue de la page 293
1 2 ... 289 290 291 292 293 294 295 296 297 298 299 ... 787 788

Commentaires sur ces manuels

Pas de commentaire