DS1E1 Facility Data Link (FDL) Errors (second half) — AT&T-54016 mode:
Slot Slot identifier.
Conn Connector identifier.
Valid Intervals Number of previous time intervals for which valid data was
collected. The value is 96 unless the interface was brought on line
within the last 24 hours. In this case, the value is the number of
complete 15-minute intervals since the interface has been on line.
Totals PCVs Number of Path Code Violations that a DS1 interface encountered
in the previous 24-hour interval.
Totals LESs Number of Line Errored Seconds that a DS1 interface encountered
in the previous 24-hour interval.
Total BESs Number of Burst Errored Seconds that a DS1 interface encountered
in the previous 24-hour interval.
Totals DMs Number of Degraded Minutes that a DS1 interface encountered in
the previous 24-hour interval.
Total LCVs Number of Line Code Violations that a DS1 interface encountered
in the previous 24-hour interval.