show isdn bri
2-369
alerts
Displays all enabled circuits that are not active. Use this display to identify the ports that
are not working. The table includes the following information:
Sample Display – show isdnbri alerts
ISDN BRI Modules on Alert:
--------------------------
DSL Line BChannel Tmr Tmr
Slot Conn State ID Number MTU TE State Loopback 3 4
---- ---- -------- ---- -------- ---- --------------- -------- --- ---
1 12 Init 0 1301102 400 Deactivated Disabled 10 750
1 32 Init 1 1301302 400 Activated Disabled 10 750
Slot Slot identifier; ranges from 1 to 14.
Conn Connector’s instance identifier; ranges from 1 to 4.
State State of the line driver: Disabled, Down, Init (initializing), Not
Present (enabled but not yet started), or Up.
DSL ID ID of this Digital Subscriber Loop interface.
Line Number Line number for this line instance.
MTU Acceptable Link Access Protocol D-channel (LAPD) Maximum
Transfer Units.
TE State Terminal Endpoint state of the S/T interface: Inactive (1), Sensing
(2), Deactivated (3), Await Signal (4), Identify Input (5),
Synchronized (6), Activated (7), Lost Framing (8).
B Channel Loopback Indicates whether B Channel Loopback is enabled. Used for
conformance testing.
Timer 3 Maximum amount of time (in seconds) the router has to activate the
S/T interface.
Timer 4 Amount of time in milliseconds the router waits for the line to
recover from a deactivated state.