show sync
2-571
Sample Display – show sync stats
SYNC Module I/O Statistics:
---------------------------
Receive Receive Transmit Transmit Total
Slot Conn Circuit Bytes Frames Bytes Frames Errors
---- ---- ------- ---------- ---------- ---------- ---------- ----------
5 1 S51 12547667 242153 12750286 246188 7
5 2 S52 12545913 242593 12752036 245763 2
2 entries in table.
system errors [circuit [
<circuit name>
] ]
Displays statistical information about system errors for all circuits or for a specific circuit.
The table includes the following information:
Slot Slot identifier; ranges from 1 to 14.
Conn Connector identifier; ranges from 1 to 4.
Circuit Name of the circuit associated with this line.
Receive Rejects Number of reject frames received.
Transmit Rejects Number of reject frames transmitted.
T1 Timeouts Number of T1 timeouts detected. The T1 timer is the link
retransmission timer. Link control frames are retransmitted when the
T1 expires. This timer tracks the number of timeouts.
Memory Errors Number of memory errors detected. A memory error occurs when
the DMA cycle expires without obtaining the bus within 26 ms.
Memory errors may indicate faulty hardware. If this count exceeds
five, call your customer service representative.