Connecting BayStack AN and ANH Systems to a Network
C-4
Network paths composed of three or four repeaters must also comply with the
following additional restrictions.
Network Path Containing Three Repeaters
In the longest path containing three repeaters, no transmit-end or receive-end fiber
link can be longer than 400 meters (m).
Network Path Containing Four Repeaters
In the longest path containing four repeaters:
No more than three links are maximum-length coaxial segments.
No fiber link is longer than 500 m; or, if one or more is longer, the total of all
fiber links does not exceed 2500 m (2740 m if all are 10Base-FB).
Configuring a Single ANH
The basic ANH configuration consists of one ANH, one local management
console, and as many as nine 10Base-T devices in a standalone local area network
configuration.
You can directly connect as many as eight 10Base-T Ethernet stations into a local
Ethernet segment using a single 8-port ANH.
Table C-1. IEEE 802.3 Maximum Segment Links
Segment Type Maximum Segment Length (m)
10Base-5 (coaxial) 500
10Base-2 (coaxial) 185
10Base-T 100
10Base-FB 2000
10Base-FL 2000
FOIRL 1000
AUI drop 50 (2-m allowance + 48-m excess)