Connecting BayStack AN and ANH Systems to a Network
A-10
Displaying Parameter Settings
Display the router parameter settings to determine
Whether the AN/ANH is set to boot using a local boot image or a remote boot
image
Whether the AN/ANH is set to configure using a local configuration file or a
remote configuration file
The configuration of the synchronous and Ethernet connectors
Enter the following Technician Interface command to display the AN/ANH
parameter settings:
getcfg
The following sample responses show the default settings for an AN or ANH with
one Ethernet and two synchronous interfaces:
Boot Options
boot image=network
boot config=network
Netboot Parameters:
XCVR1..None
COM1...EZ-Install
COM2...EZ-Install
The possible boot image and boot config settings are network and local.
If the setting is
network, the AN/ANH requests the boot image or configuration
file from a BOOTP server when booting. If the setting is
local, the AN/ANH
uses the boot image or configuration file stored in the Flash card file system.
The
XCVR parameter shows the current setting of the AN/ANH Ethernet
connectors. The
COM parameters show the current settings of the AN/ANH
synchronous connectors.
The possible settings for synchronous connectors are as follows:
EZ-Install (the default setting)
The IP address, next-hop IP address, subnet mask, and WAN protocol (Bay
Networks HDLC or Frame Relay)
Vue de la page 129