Sample Display - show t1 alerts
T1 Modules on Alert:
--------------------
Frame Line B8ZS Clock
Slot Conn Circuit Type Bldout Support Mode MiniDacs Configuration
---- ---- ------- ----- ------ ------- -------- ------------------------
2 1 T1-21 ESF 1 Off Internal 1111111111111111IIIIIIII
2 2 T1-22 ESF 1 Off Slave 2222222222222222IIIIIIII
Found 2 matches out of 2 entries in table.
base
[
circuit
<circuit name>
]
Displays the base level information for all T1 circuits or a specific circuit. For definitions
of the columns in the table, see the
alerts
command.
Sample Display - show t1 base
T1 Modules:
-----------
Frame Line B8ZS Clock
Slot Conn Circuit Type Bldout Support Mode MiniDacs Configuration
---- ---- ------- ----- ------ ------- -------- ------------------------
2 1 T1-21 ESF 1 Off Internal 1111111111111111IIIIIIII
2 2 T1-22 ESF 1 Off Slave 2222222222222222IIIIIIII
2 entries in table.