Using Technician Interface Scripts
2-678
303560-A Rev 00
Sample Display - show sync system
SYNC Module System Errors:
--------------------------
Receive Transmit T1 Memory
Slot Conn Circuit Rejects Rejects Timeouts Errors
---- ---- ------- ---------- ---------- ---------- ----------
5 1 S51 0 0 0 0
5 2 S52 0 0 0 0
2 entries in table.
Sample Display - show sync system errors circuit s31
SYNC Module System Errors:
--------------------------
Receive Transmit T1 Memory
Slot Conn Circuit Rejects Rejects Timeouts Errors
---- ---- ------- ---------- ---------- ---------- ----------
3 1 S31 0 0 0 0
Found 1 match out of 4 entries in table.
transmit errors
[
circuit
[
<circuit name>
]
]
Displays statistical information about transmission errors for all circuits or for a specific
circuit. The table includes the following information:
Slot Slot identifier; ranges from 1 to 14.
Conn Connector identifier; ranges from 1 to 4.
Circuit Name of the circuit associated with this line.
Underflow Frames Number of retransmission underflow errors. These occur when the
device’s FIFO buffer empties before the device obtains the next
DMA request.