Using Technician Interface Scripts
2-170
303560-A Rev 00
hwfilters
Displays all hardware filter configurations on the router.
Sample Display - show circuits hwfilters
Hardware Filters Modules:
-------------------------
Line Maximum Current Used Dropped
Slot Conn Circuit State Type Tbl Siz Tbl Siz Entries Frames
---- ---- -------- -------- ------ ------- ------- ------- ----------
0 entries in table.
receive errors
[
<circuit name>
]
Displays the receive error statistics for all circuits or for a specific circuit.
Sample Display - show circuits receive errors
CSMACD Module Receive Errors:
-----------------------------
Checksum Alignment Overflow Frames
Slot Conn Circuit Errors Errors Errors Too Long
---- ---- -------- ---------- ---------- ---------- ----------
3 1 E31 7 7 0 0
3 2 E32 0 0 0 0
3 3 E33 0 0 0 0
3 4 E34 0 0 0 0
4 entries in table.
HSSI Module Receive Errors:
---------------------------
Frames
Slot Conn Circuit CRC Errors Overruns Aborts Too Long
---- ---- ------- ---------- ---------- ---------- ----------
0 0 0 0 0 0
0 0 0 0 0 0
2 entries in table.
TOKEN RING Receive Errors:
--------------------------
Line Burst
Slot Conn Circuit Errors Errors
---- ---- -------- ---------- ----------
2 1 O21 0 0
1 entry in table.