Using Technician Interface Scripts
2-108
303560-A Rev 00
Sample Display - show atm line sample 5 circuit A51
ATM Sampled Data over 5 seconds
---------------------------------
Rx Tx Rx Lack of Tx Lack of
Slot Conn Circuit Frames Frames Resources Resources
---- ---- -------- ---------- ---------- ---------- ----------
5 1 A51 0 0 0 0
Found 1 match out of 2 entries in table.
stats
[
circuit
<circuit name>
]
Displays the total number of bytes and frames received and transmitted for the specified
circuit or for all circuits. In addition, displays the total number of errors. For more
information on column definitions, see the
alerts command.
Sample Display - show atm line stats
ATM Module I/O Statistics:
--------------------------
Receive Receive Transmit Transmit Total
Slot Conn Circuit Bytes Frames Bytes Frames Errors
---- ---- -------- ---------- ---------- ---------- ---------- ----------
4 1 A41 0 0 2190795656 42405432 16
5 1 A51 0 0 1793648210 86273694 3
2 entries in table.
Sample Display - show atm line stats circuit A51
ATM Module I/O Statistics:
--------------------------
Receive Receive Transmit Transmit Total
Slot Conn Circuit Bytes Frames Bytes Frames Errors
---- ---- -------- ---------- ---------- ---------- ---------- ----------
5 1 A51 0 0 1793648210 86273694 3
Found 1 match out of 2 entries in table.