Avaya Using Technician Interface Scripts Manuel d'utilisateur Page 286

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 892
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 285
Using Technician Interface Scripts
2-238
303560-A Rev 00
receive errors [circuit
<circuit name>
]
Displays receive errors for all circuits or for a specific circuit. The table includes the
following information:
Sample Display - show ds1e1 receive
DS1E1 Logical Line Receive Errors:
----------------------------------
Slot Slot identifier.
Conn Connector identifier.
Log Line Logical line number for this line.
Circuit Name of the circuit associated with this line.
Null Frames Number of frames containing no data bytes received.
Short Frames Number of frames received with only one or two data bytes.
CRC Errors Number of frames received with CRC errors.
Long Frames Number of frames received that exceeded the MTU size.
Abort Frames Number of frames received with abort errors.
Slot
----
Conn
----
Log
Line
----
Circuit
------------
Null
Frames
------
Short
Frames
------
CRC
Errors
------
Long
Frames
------
Abort
Frames
------
2 1 1 Boston 0 1256000
2 1 2 Chicago 00000
2 1 1 Seattle 0 40000
3 entries in table.