Sample Display - show nml circuits
NML Circuit Table
-----------------
CUG Security SAID Security
Circuit Port Value Type Value Action
-------- -------- ------------ -------- ------------ ----------
F31 1 0 Check 0 Forward
E21 2 22 Add 0 Drop
2 Entries.
disabled
Displays only NML circuits that are disabled. The display contains the same information
the
circuits
command produces.
enabled
Displays only NML circuits that are enabled. The display contains the same information
the
circuits
command produces.
Security Type Type of security configured -- Add, an access circuit; Check, a
trunk circuit; or Drop, a transient internal state.
SAID Value Circuit’s security access ID.
Security Action How to handle a packet if it matches a CUGID in the circuit’s
security list: Drop or Forward. If the action is Drop, the list is an
exclusive list and the port drops all frames labelled with the
CUGID. If the action is Forward, the port forwards frames labelled
with the CUGID to the attached LAN.