Interface Roles
Nortel Networks interface redundancy software determines which interface in a
redundancy group becomes the active interface if the current active interface fails.
The software also determines the priority for each of the remaining members of
the group to become the active interface.
Determining the Active Interface
When you boot a router configured with interface redundancy, the designated
primary interface has 12 seconds to become active. If it does become active, data
transmission begins normally.
If the designated primary interface does not become active within 12 seconds, the
redundant interface with the highest priority becomes the active interface, and
transmission begins. The 12-second initialization period occurs only once, and
applies only to the designated primary interface. After initialization, all redundant
interfaces are ready to become active immediately if the active interface fails.
Reset Active Feature
Interface redundancy includes a Reset Active feature that allows you to force the
interface you have designated as primary to become the active interface. Using
this feature may improve network performance. Refer to Chapter 4 for
information about accessing the Reset Active feature.
Determining Priority
The redundant interface with the highest priority becomes the active interface if
the active interface fails.
During startup, if the designated primary interface fails to become active, the
following interfaces become active, in this order:
1. Redundant interfaces on the same slot as the designated primary interface
2. Redundant interfaces on other slots