Avaya Troubleshooting Routers Guide de dépannage Page 243

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 268
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 242
Using the Technician Interface to Configure and Run Packet Capture
308656-14.00 Rev 00
B-49
Parameter: Reference
Packet Capture supports four Reference parameters.
Default: 1
Options: 1
|
2
|
3
Function: Indicates the field in the packet to match.
Instructions: Set to one of the following:
1 for the first byte of the packet. Specify this value if you want the
copied portion of the packet to contain media access control (MAC)
information.
2 for data link.
3 for multicast. Specify this value if you want to use a special filter to
make sure the rightmost bit of a byte is 1.
To specify a multicast bit for Ethernet, specify 3. Then, set the offset to 0.
To specify a source routing bit for token ring, specify 3. Then, set the
offset to 6.
Packet
Direction MIB Attribute Name
Filter
No. MIB Object ID
Attribute
No.
Incoming wfPktCaptureRxFltr1Ref 1 1.3.6.1.4.1.18.3.4.21.1.1.16 16
Incoming wfPktCaptureRxFltr2Ref 2 1.3.6.1.4.1.18.3.4.21.1.1.26 26
Outgoing wfPktCaptureTxFltr1Ref 1 1.3.6.1.4.1.18.3.4.21.1.1.21 21
Outgoing wfPktCaptureTxFltr2Ref 2 1.3.6.1.4.1.18.3.4.21.1.1.32 32