Monitoring Software Compression Using the BCC show Commands
117352-D Rev. 00
C-5
show wcp stats error2
The
show wcp stats error2
command displays information about error
conditions pertaining to WCP compression on the connection.
The output includes the following information:
Data Out of Sequence Number of instances registered of the data-out-of-sequence
condition.
Rexmit Out of
Sequence
Number of times that an acknowledgment was retransmitted out
of sequence.
Rexmit Time-Outs Number of timeout messages retransmitted.
Exceeded Ks Number of times that K was exceeded. (WCP maintains a
transmit history of data packets for a specified range called “K.” A
packet can be retransmitted if it remains in the range of packets
kept in the transmit history. If a packet is outside the range
specified by K, it cannot be retransmitted.
Channel Number The number of the channel on which this virtual circuit is running.
Circuit Name Circuit name of the interface.
Vc Id Identification of the virtual circuit.
Reset Packets (Tx) Number of reset packets transmitted.
Reset Packets (Rx) Number of reset packets received.
Re-transmit Request
(Tx)
Number of retransmit request packets transmitted.
Re-transmit Request
(Rx)
Number of retransmit request packets received.
Re-transmit Naks (Tx) Number of negative acknowledgments transmitted
Re-transmit Naks (Rx) Number of negative acknowledgments received