Site Manager Parameters
117352-D Rev. 00
A-13
Parameter: Fallback Compression Mode
Path: Configuration Manager > Protocols > Hi/fn LZS > Interfaces
Default: Software CPC
Options: Software CPC
|
None
Function: When a circuit on this line cannot register for hardware compression due to a
lack of hardware-context memory, this parameter determines whether data will
be compressed by software or remain uncompressed.
Instructions: If you want data to be compressed by software on a circuit that cannot register
for hardware compression, set this parameter to Software CPC.
If you want data to remain uncompressed on a circuit that cannot register for
hardware compression, set this parameter to None. None is a good choice for
very high-speed links.
MIB Object ID: 1.3.6.1.4.1.18.3.4.22.5.1.8