Avaya Configuring Data Compression Services Manuel d'utilisateur Page 49

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 103
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 48
Customizing Data Compression
117352-D Rev. 00
3-3
To specify the compression mode for a circuit, complete the following tasks:
Maximizing Throughput
Each side of the link has both a compression and decompression history and a
lookup table. The compression and decompression histories maintain a record of
data that has already traveled across the network. The
lookup tables maintain
pointers to redundant strings and the offset and length tokens that replace each of
those strings.
You can specify either 8 KB or 32 KB of local memory to maintain a compression
history. When you make this choice, be aware that you are allocating more
memory than the History Size parameter value indicates.
5. Set the
Compression Mode
parameter.
Click on
Help
or see the parameter
description on page A-4
.
6. Click on
Done
. You return to the Configuration Manager
window.
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose
Protocols
.
The
Protocols menu opens
.
2. Choose
WCP
. The WCP menu opens.
3. Choose
Interfaces
. The WCP Circuit Interfaces List window
opens.
4. Select a circuit from the list.
5. Set the
Compression Mode
parameter.
Click on
Help
or see the parameter
description on page A-9
.
6. Click on
Done
. You return to the Configuration Manager
window.
Site Manager Procedure
(continued)
You do this System responds
Vue de la page 48
1 2 ... 44 45 46 47 48 49 50 51 52 53 54 ... 102 103