Using Technician Interface Software
7-26
308657-14.00 Rev 00
Enabling and Disabling Diagnostics During the Power-Up Sequence
You can turn on and off the diagnostics for the AN/ANH or ARN platforms for
subsequent power cycles.
AN and ANH Power-Up Diagnostic Option
You can use the
set
command on AN and ANH routers to disable or reenable the
power-up diagnostics.
set
[
-P0
|
P1
]
Examples:
Pressing the Reset button on the back panel of the AN for more than 5 seconds
initiates a cold boot; power-up diagnostics execute even when disabled by the
set -P0
command.
ARN Diagnostics On/Off Option
For ARN platforms only, the Technician Interface
diags
command supports an
option to enable or disable diagnostics, effective the next time you cycle power on
the router. Disabling the diagnostics results in a faster boot time, but leaves the
hardware components unverified.
The syntax for this option is as follows:
diags
[-
<on|off>
] [
<slot_id>
]
set -P0
The router skips power-up diagnostics at subsequent restarts.
set -P1
The router executes all power-up diagnostics at subsequent
restarts.