Configuring MPLS Services
A-10
305754-A Rev 00
Parameter: Vc Range Maximum VCI
Path: Configuration Manager > Circuits > Edit Circuits > Edit > MPLS > LDP >
Default VC
Default: 65535
Options: 32 to 65535
Function: Identifies the largest virtual channel number that MPLS can use when creating
SVCs. The VCI is part of the cell header. The header can contain a maximum of
16 VCI bits. This bit range allows for channel identifiers from 32 to 65,535.
Instructions: Enter a value from 32 to 65535.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.16.1.3.1.9
Parameter: Xmt Peak Cell Rate
Path: Configuration Manager > Circuits > Edit Circuits > Edit > MPLS > LDP >
Default VC
Default: 0
Options: 128 to 353207
Function: S
pecifies the upper traffic limit, in cells/s, that the MPLS egress connection can
submit. The default value, 0, indicates that the PCR is attempting to run at line
rate.
Instructions: Set the peak cell rate within the specified range.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.16.1.3.1.10