Site Manager Parameters
117374-C Rev 00
A-85
Parameter: Default Vcl VPI
Path: Configuration Manager > Circuits > Edit Circuits > Edit > MPLS > LDP >
Default VC
Default: 0
Options: 0 to 255
Function: Identifies the virtual path of the MPLS default VC. The VPI is part of the cell
header. The header can contain a maximum of 8 VPI bits for a UNI connection.
This bit range allows for path identifiers from 0 to 255.
Instructions: Enter a value from 0 to 255.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.16.1.3.1.5
Parameter: Default Vcl VCI
Path: Configuration Manager > Circuits > Edit Circuits > Edit > MPLS > LDP >
Default VC
Default: 32
Options: 32 to 65535
Function: Identifies the virtual channel of the MPLS default VC. The VCI is part of the
cell header. The header can contain a maximum of 16 VCI bits. This bit range
allows for channel identifiers from 32 to 65,535.
Instructions: Enter a value from 32 to 65535.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.16.1.3.1.6
Parameter: Vc Range VPI
Path: Configuration Manager > Circuits > Edit Circuits > Edit > MPLS > LDP >
Default VC
Default: 0
Options: 0 to 255
Function: Identifies the virtual path that MPLS can use when creating SVCs. The VPI is
part of the cell header. The header can contain a maximum of 8 VPI bits for a
UNI connection. This bit range allows for path identifiers from 0 to 255.
Instructions: Enter a value from 0 to 255.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.16.1.3.1.7