Configuring ATM and MPLS Services
5-48
117374-C Rev 00
For additional information about the MBS, see “Using the MBS” on page 1-26.
For information about setting the maximum AAL CPCS transmit SDU size, see
Modifying the Maximum AAL CPCS SDU Size
” on page 5-51.
Using the BCC
To change the MBS value for signaling VCs, navigate to the signaling VC prompt
(for example,
box; atm/11/1; signaling/11/1; signaling-vc/11/1/0/5) and enter:
tx-burst-size
<integer>
integer
is the MBS value that you want the signaling VC to use.
For example, the following command changes the MBS value to 80 cells:
signaling-vc/11/1/0/5# tx-burst-size 80
signaling-vc/11/1/0/5#
To change the MBS value for ILMI VCs, navigate to the ILMI VC prompt (for
example,
box; atm/11/1; signaling/11/1; ilmi-vc/11/1/0/16) and enter:
tx-burst-size
<integer>
integer
is the MBS value that you want the ILMI VC to use.
For example, the following command changes the MBS value to 80 cells:
ilmi-vc/11/1/0/16# tx-burst-size 80
ilmi-vc/11/1/0/16#