Avaya Configuring ATM and MPLS Services Manuel d'utilisateur Page 155

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 529
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 154
Customizing Signaling
117374-C Rev 00
5-7
Specifying the Maximum Number of SVC Applications
You can specify the maximum number of SVC applications that you want to
operate on the circuit. The number of applications corresponds to the number of
LANE or IP (RFC 1577) clients allowed for the circuit.
By default, you can have up to 20 SVC applications on the circuit. However, you
can specify a value from 1 to 32767.
Using the BCC
To change the maximum number of SVC applications, navigate to the signaling
prompt (for example,
box; atm/11/1; signaling/11/1
) and enter:
svc-applications-maximum
<integer>
integer
is a value from 1 to 32767.
For example, the following command sets the maximum number of SVC
applications on the ATM circuit to 100.
signaling/11/1# svc-applications-maximum 100
signaling/11/1#