Avaya Configuring ATM and MPLS Services Manuel d'utilisateur Page 418

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 529
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 417
Configuring ATM and MPLS Services
A-52
117374-C Rev 00
Parameter: TDisc
Path: Configuration Manager > Protocols > ATM > ATM Signaling
and
Configuration Manager > Circuits > Edit Circuits > Edit > ATM > ATM
Signaling
Default: 4
Options: 1 to 180
Function: Specifies the SAAL Data Link Disconnect timer value (in seconds). This
internal timer alerts upper layers that the link is down. The timer begins if the
entire link goes down for any reason.
When the link goes down, the SAAL sends a DISCONNECT REQUEST
message to the upper-layer application manager. The SAAL sends a disconnect
request every time the SAAL Data Link Disconnect timer expires and continues
to send this message until the link becomes operational.
Instructions: Accept the default, 4, or enter a value from 1 to 180.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.33
Parameter: T398
Path: Configuration Manager > Protocols > ATM > ATM Signaling
and
Configuration Manager > Circuits > Edit Circuits > Edit > ATM > ATM
Signaling
Default: 4
Options: 1 to 24
Function: Specifies the Drop Party Sent timer value (in seconds). This timer applies to
multipoint connections only and begins when the circuit sends a DROP PARTY
message to a party (the receiver of the message) on the network.
The Drop Party Sent timer stops when the circuit receives a DROP PARTY
ACKNOWLEDGE message (indicating that the end point used for the party has
been released) or a RELEASE message (indicating that the end point used for
the party has been released and there are no remaining parties).
Instructions: Accept the default, 4, or enter a value from 1 to 24.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.34
Vue de la page 417
1 2 ... 413 414 415 416 417 418 419 420 421 422 423 ... 528 529

Commentaires sur ces manuels

Pas de commentaire