Avaya Configuring ATM and MPLS Services Manuel d'utilisateur Page 417

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 529
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 416
Site Manager Parameters
117374-C Rev 00
A-51
Parameter: T322
Path: Configuration Manager > Protocols > ATM > ATM Signaling
and
Configuration Manager > Circuits > Edit Circuits > Edit > ATM > ATM
Signaling
Default: 4
Options: 1 to 24
Function: Specifies the Status Enquiry Sent timer value (in seconds). This timer begins
when the circuit sends a STATUS ENQUIRY message to the network. This
message checks the validity of a call by requesting the call state (that is, active,
in progress, or null). The Status Enquiry Sent timer stops when the circuit
receives a STATUS message from the network.
If the timer expires before the circuit receives a STATUS message, the circuit
can transmit as many STATUS ENQUIRY messages as specified with the Num
Stat Enquiries ReXmitted parameter (see the parameter description on A-54
). If
the circuit still does not receive a response, the circuit clears the call.
Instructions: Accept the default, 4, or enter a value from 1 to 24.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.32