Creating Line Pools
114062 Rev. A 7-27
Parameter: Signal Level (dB)
Default: 0.0 dB
Options: -15 dB
| -7.5 dB | 0.0 dB | 0.5 dB | 0.8 dB | 1.1 dB | 1.5 dB
Function: Specifies the T1 transmit power level in decibels (dB).
The DS1 values of -15 and -7.5 dB are long-haul and the carrier
determines these values if 0.0 dB is not sufficient.
The DSX1 values of 0.0, 0.5, 0.8, 1.1, and 1.5 dB are short-haul and
correlate with cable length as follows:
Instructions: Specify the decibel level according to the length of the cable or as the
carrier specifies.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.3.1.6
Parameter: Setup Alarm Threshold (seconds)
Default: 2 seconds
Range: 2 to 10 seconds
Function: Specifies the time interval during which MCT1 tolerates a performance
defect or anomaly. If the performance defect or anomaly is still present
when this time interval expires, MCT1 records a performance failure and
logs an event message.
Instructions: Set the timer value.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.3.1.7
0.0 dB 0 to 133 ft
0.5 dB 133 to 266 ft
0.8 dB 266 to 399 ft
1.1 dB 399 to 533 ft
1.5 dB 533 to 655 ft