Creating Line Pools
114062 Rev. A
7-9
Site Manager redisplays the Pools window with three new buttons (Edit,
Apply, and Delete) that allow you to edit the newly created pool (Figure
7-9).
Pool ID Parameter
Use the following description when you configure the Pool ID parameter.
Parameter: Demand/Backup/Bandwidth-on-Demand Pool ID
Default: None
Range: 1 to 255
Function: Identifies the line pool by assigning it a number.
Instructions: Enter a number between 1 and 255, inclusive, as the line pool ID.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.4.5.1.6 (Demand Pool ID)
1.3.6.1.4.1.18.3.5.1.4.5.1.5 (Backup Pool ID)
1.3.6.1.4.1.18.3.5.1.4.5.1.35 (Bandwidth Pool ID)
WAN Serial Interface Type Parameter
Use the following description as a guideline when you configure the
WAN Serial Interface Type parameter.
Parameter: WAN Serial Interface Type
Default: Sync
Options: Sync
|
Async
Function: Determines whether this interface uses synchronous communication or
asynchronous communication.
Instructions: If you are using asynchronous PPP, select Async. Otherwise, accept the
default.
MIB Object ID: 1.3.6.1.4.1.18.3.4.5.1.109
Note:
These three new buttons on the Pools window appear only if a line pool
already exists.